YVFE3 225M-2/4/6/8 IE3 VF 3-Phase Asynchronous Motor
-
Common faults and troubleshooting methods are as follows when this series of motor fails during the operating process.If the motor shell is live, reasons may be:
1) bad grounding;
2) damp winding, insulation damage or dirt on the terminal board;
3) frayed lead wire.
Relevant solutions are:
1) check ground connection;
2) winding drying, repair insulation damage and clean the wiring board;
3) repair or replace the insulated wire.If the motor has abnormal sound at operating, possible reasons are:
1) motion of defective phase;
2) bearing damage and lack of oil;
3) mechanical rubbing or rubbing between stators and rotors;
1) check electrical connections and eliminate phase failure;
2) replace the bearing or grease;
3) check the stator bore for any debris such as paint lump, then process.If the motor has abnormal vibration during operation, reasons are:
1) loose installation of motor or load;
2) the coupling or pulley is eccentric or unbalanced;
3) the shaft is bent after impact;
4) poor rotor balancing.
When facing this condition, solutions are:
1) check and fasten the foot bolt;
2) calibrate the eccentricity or rebalance;
3) replace the rotor or shaft;
4) rebalance.
Type | Rated Power | Current/380V | Current/400V | Speed | Sync. Speed | Eff. | Power Factor | Locked torque | Locked current | Max. torque | Rated Torque | Moment of Inertia | No-Load Noise | Weight |
kW | A | A | r/min | r/min | % | Cosφ | Rated Torque | Rated Current | Rated Torque | N•m | kg•m2 | dB(A) | Kg | |
YVFE3-225M-2 | 45 | 80.8 | 76.8 | 2975 | 3000 | 94 | 0.9 | 2 | 8 | 2.3 | 143.2 | 0.27 | 103 | 288 |
YVFE3-225M-4 | 45 | 84.4 | 80.2 | 1485 | 1500 | 94.2 | 0.86 | 2 | 7.4 | 2.3 | 286.5 | 0.64 | 94 | 339 |
YVFE3-225M-6 | 30 | 59.1 | 56.2 | 990 | 1000 | 92.9 | 0.83 | 2 | 6.9 | 2.1 | 286.5 | 0.64 | 89 | 304 |
YVFE3-225M-8 | 22 | 47.3 | 45 | 730 | 750 | 90.6 | 0.78 | 1.9 | 7 | 2 | 280.1 | 0.64 | 89 | 295 |
0102030405060708