English
Leave Your Message
YQ-14-6/8/10/12 Squirrel Cage 3 Phase Asynchronous Motor

Squirre Cage 3-Phase Asynchronous Motor YQ

YQ-14-6/8/10/12 Squirrel Cage 3 Phase Asynchronous Motor

Frame Size

14

No. of Poles

6P, 8P, 10P, 12P

Rated Power

250KW~800KW

Rated Voltage

380V

Rated Frequency

50/60HZ

Insulation

130 (B) Grade

Protection Grade

IP23

Connection

Cooling Method

IC01

Duty

S1

Vibration

≤2.3mm/s

Altitude

≤1000m

Ambient temperature

-15℃ ~ +40℃

Brand name

SIMO MOTOR

Humidity

Average monthly peak relative humidity is 90%


*Note: Motors can be customized according to customer’s requirements.

    Motor Description

    • YQ series media size motor can drive various kinds of mechanical equipment, such as blowers, compressors, pumps, crushers, stocker moving machines. It can serve as the prime movers in coalmines, mechanical industries, power plants and various industrial enterprises.
      YQ series squirrel cage three-phase asynchronous motor measures up the JB563-64 technical standard. This series motor is protection type, but they can be designed into tube ventilation type if customer request.
      The protection style motor have to be indoor installed, which the altitude not more than 1000 m, the ambient temperature from 0'C up to 40C, the air should be clean, none-acid, non-alkali. The motor don't allowed to work in the atmosphere which is explosive and dusty.
      When the ambient temperature exceeds the above limit or the air is unclean, the Tube Ventilation type should be used. Here, the temperature of the air which enter the both sides of the motor should be 0℃ to 40℃, meanwhile the air pressure which inside the tube and inner motor should higher than that of the ambient air, the blower and filter should be equipped on at necessary time.
      The full voltage start is allowed for YQ series squirrel cage motor. The ratio of initial starting torque and its rated value is shown in table No.3, as well as that of initial starting current and its rated vale. If customer’s electricity net can’t bear the full voltage start, reducing voltage start also suitable. However, the starting torque and the starting voltage fall at square relation.

    Outline Dimensions

    YQ-14-3xsw

    Motor Parameters

    Frame Size Power Voltage Speed Sync. Speed Stator Current Eff. Power Factor Starting Torque Starting Torque Max. Torque Cooling Air Volume Rotor Fly-wheel Moment Max.Fly-wheel Moment for Driven Mechine Weight
    KW V r/min r/min A % Cosø Rated Torque Rated Torque Rated Torque KG
    146-6 560 380 988 1000 1040 94 0.87 6.0 1.0 1.8 151
    147-6 630 380 989 1000 1168 94.2 0.87 6.0 1.0 1.8 175
    148-6 710 380 988 1000 1297 94.5 0.88 6.0 1.0 1.8 194
    1410-6 800 380 989 1000 1458 94.7 0.88 6.0 1.0 1.8 213
    146-8 400 380 740 750 781 93.6 0.83 6.0 1.0 1.8 165
    147-8 450 380 740 750 876 94 0.83 6.0 1.0 1.8 175
    148-8 500 380 740 750 972 94.2 0.83 6.0 1.0 1.8 194
    1410-8 560 380 740 750 1086 94.4 0.83 6.0 1.0 1.8 213
    147-10 355 380 590 600 705 93.3 0.82 5.5 1.0 1.8 211
    148-10 400 380 590 600 793 93.5 0.82 5.5 1.0 1.8 234
    1410-10 450 380 590 600 890 93.7 0.82 5.5 1.0 1.8 257
    146-12 250 380 495 500 540 92.6 0.76 5.5 1.0 1.8 183
    147-12 280 380 495 500 595 92.8 0.77 5.5 1.0 1.8 211
    148-12 315 380 495 500 668 93 0.77 5.5 1.0 1.8 234
    1410-12 355 380 495 500 752 93.2 0.77 5.5 1.0 1.8 257

    Application

    description1