English
Leave Your Message
YKK-400-2/4/6/8/10/12 6KV High Efficiency Air Cooling 3 Phase Asynchronous Motor

Efficiency Air Cooling 3-Phase Asynchronous Motor YKK

YKK-400-2/4/6/8/10/12 6KV High Efficiency Air Cooling 3 Phase Asynchronous Motor

Frame Size

H400mm

No. of Poles

2P, 4P, 6P, 8P, 10P, 12P

Rated Power

185KW~560KW

Rated Voltage

6KV

Rated Frequency

50/60HZ

Insulation

155 (F) Grade

Protection Grade

IP54/IP55

Mounting Type

IM B3

Cooling Method

I611

Duty

S1

Connection

Y

Vibration

≤2.3mm/s

Altitude

≤1000m

Ambient temperature

-15℃ ~ +40℃

Place of Origin

Xi’an, China

Brand name

SIMO MOTOR

Humidity

Average monthly peak relative humidity is 90%


*Note: Motors can be customized according to customer’s requirements.

    Motor Description

    • YKK series high efficiency air cooling 3 phase asynchronous motor complies with IEC standard. In order to achieve a significant market share it is essential for high-efficiency motors to meet national/regional standards for assigned powers in relation to mechanical dimensions (such as frame-size, flanges). There are a number of national/regional frame assignment standards (EN 50347, JIS C 4212, NBR 17094, NEMA MG13, SANS 1804 and others) but there is no IEC standard. As this standard (IEC 60034-30-1) defines energy-efficiency classes independent of dimensional constraints it may not be possible in all markets to produce motors with higher efficiency classes and maintain the mechanical dimensions of the national/regional standards.

      IE codes are not limited to motors but may be used to classify other components such as frequency converters and gearboxes. However, it is anticipated that other components are rated with a comparable system: IE1 meaning low efficiency up to IE5 meaning the highest efficiency. Combinations of components (such as power drive systems) will need a combined efficiency rating. That rating should not be an IE code in order to avoid confusion. It will be defined in other IEC standards. The efficiency levels in this standard for 50 Hz and 60 Hz are not always entirely consistent across all numbers of poles and over the whole power range.

    Outline Dimensions

    YKK-400-4yhl

    Motor Parameters

    Type Rated Power kW Rated Current A Rated Speed r/min Eff. % Power Factor Cosφ Locked Torque Locked Current Max. Torque Load moment of inertia Kg.m2 Weight Kg
    Rated Torque Rated Current Rated Torque
    YKK4001-2 355 42.8 2975 92.7 0.86 0.6 7 1.8 24 2575
    YKK4002-2 400 48.1 2975 93 0.86 0.6 7 1.8 27 2665
    YKK4003-2 450 54 2975 93.3 0.86 0.6 7 1.8 30 2745
    YKK4004-2 500 59.8 2975 93.6 0.86 0.6 7 1.8 33 2815
    YKK4005-2 560 66.8 2975 93.8 0.86 0.6 7 1.8 36 3160
    YKK4001-4 355 42.8 1485 92.8 0.86 0.7 6.5 1.8 122 2750
    YKK4002-4 400 48.1 1485 93 0.86 0.7 6.5 1.8 136 2830
    YKK4003-4 450 54 1485 93.2 0.86 0.7 6.5 1.8 151 2940
    YKK4004-4 500 59.9 1485 93.4 0.86 0.7 6.5 1.8 151 3160
    YKK4005-4 560 66.9 1485 93.6 0.86 0.7 6.5 1.8 151 3365
    YKK4002-6 280 35.5 990 92.5 0.82 0.7 6 1.8 283 2770
    YKK4003-6 315 39.8 990 92.8 0.82 0.7 6 1.8 298 2920
    YKK4004-6 355 44.3 990 93 0.83 0.7 6 1.8 313 3130
    YKK4005-6 400 49.8 990 93.1 0.83 0.7 6 1.8 323 3240
    YKK4001-8 185 24.9 740 91.6 0.78 0.8 5.5 1.8 373 2665
    YKK4002-8 200 26.8 740 91.9 0.78 0.8 5.5 1.8 401 2740
    YKK4003-8 220 29.5 740 92.1 0.78 0.8 5.5 1.8 438 2830
    YKK4004-8 250 33 740 92.2 0.79 0.8 5.5 1.8 493 2900
    YKK4005-8 280 36.9 740 92.4 0.79 0.8 5.5 1.8 546 3060
    YKK4004-10 185 26.1 595 90.8 0.75 0.8 5.5 1.8 635 2890
    YKK4005-10 200 28.2 595 91.1 0.75 0.8 5.5 1.8 682 2980

    Application